Template · Published Nov 19, 2026
Dental Office Policies and Procedures Manual Template (Word)
For the owner dentist or office manager whose policies live in an old binder, a folder of OSHA forms and one person's memory. You leave with the binder itself: one numbering scheme, a table of contents for every dental policy area, six dental policies written in full, a review calendar and the 2027 dates.
The Word binder: a cover and control block, numbering and version rules, a table of contents with 82 policy slots in ten dental chapters (each marked by the rule behind it), six dental policies written in full, a readiness score and gap worksheet, a revision log, a monthly review calendar with the 2027 dates, staff acknowledgments and a retention table.
Get the free dental policies and procedures manual (Word)A dental office policies and procedures manual template is the binder that holds every written rule, numbered by chapter, versioned, reviewed on a calendar and signed by staff. CDC asks dental offices to reassess infection prevention policies at least annually (CDC, 2016). This Word template has 82 slots in ten chapters and six dental policies in full.
Key takeaways
- CDC's dental checklist expects written policies in 14 infection prevention areas, from staff immunizations to boil-water advisories, "reassessed at least annually" (CDC, Mar 2016; ClinicOps count of its section I).
- A Pennsylvania dental practice paid $140,000 to settle a HIPAA case announced Oct 9, 2026, with findings that included failing to implement required privacy policies and procedures (HIPAA Journal, 2026; 45 CFR 164.530(i)).
- From July 17, 2027, a patient's request for records must be answered within 15 calendar days instead of 30, and the signed privacy notice acknowledgment ends (HHS final rule 2026-23429). Until then the 30-day rule applies.
- Amalgam separator records must be kept at least 3 years, and a separator installed before June 14, 2017 that does not meet the current standard must be replaced by June 14, 2027 (40 CFR 441.30, 441.50).
- Since Feb 1, 2024 the ADA no longer recommends lead aprons or thyroid collars for dental x-rays, so many radiation policies are out of date unless state law still requires shielding (ADA, 2024).
- In 2,402 fraud cases, 33% happened because controls were missing, 19% because they were overridden and 18% because nobody reviewed; median loss was $126,000 at organizations under 100 employees (ACFE, 2026).
The manual at a glance: ten dental chapters
The binder has ten chapters, each with an owner and a review month, so the whole manual is read once a year without a lost December. Of the 82 slots, 32 rest on a federal rule, 7 on a state rule where your state decides the text, 17 on CDC's dental guidance, and 26 are your own decisions.
| Code | Chapter | Slots | Tied to a rule | Owner | Review |
|---|---|---|---|---|---|
| ADM | Governance and records | 5 | 3 | Office manager | January |
| PRV | HIPAA privacy and security | 11 | 11 | Privacy official | February |
| OSH | OSHA and workplace safety | 10 | 9 | Safety lead | March |
| ST | Sterilization and instrument processing | 6 | 6 | Sterilization lead | April |
| FO | Front office | 9 | 1 | Front desk lead | May |
| RAD | Radiation safety | 6 | 6 | Owner dentist | June |
| IC | Clinical and infection control | 12 | 12 | Infection prevention coordinator | July |
| EM | Emergencies | 6 | 2 | Office manager | August |
| HR | People | 8 | 6 | Office manager | September |
| FIN | Money handling | 9 | 0 | Owner dentist | October |
The full table of contents
This is the table of contents exactly as it appears in the Word file. Basis says why the slot exists. In the file, each row also has a Status column (Have, Draft or Missing) and the last column names a free ClinicOps template where one exists. Delete what does not apply: an office that never places or removes amalgam, stocks no controlled substances or uses no nitrous oxide drops those slots.
| No. | Policy | Basis | Rule, source or free template |
|---|---|---|---|
| ADM-01 | Policy on policies: writing, approval, numbering and review | Federal rule | 45 CFR 164.316(b); 164.530(i), (j) |
| ADM-02 | Roles, decision rights and who covers whom | Practice decision | Write your own |
| ADM-03 | Records retention and destruction | Federal rule | 45 CFR 164.530(j); state law for patient records |
| ADM-04 | Business associates and vendor contracts | Federal rule | 45 CFR 164.502(e) |
| ADM-05 | Emergency closure and business continuity | Practice decision | Write your own |
| PRV-01 | Privacy official, privacy policies and safeguards | Federal rule | 45 CFR 164.530(a), (c), (i) |
| PRV-02 | Notice of Privacy Practices (update by July 17, 2027) | Federal rule | 45 CFR 164.520 |
| PRV-03 | Patient access to records and images (15 days from July 17, 2027) | Federal rule | 45 CFR 164.524 |
| PRV-04 | Minimum necessary and role-based access | Federal rule | 45 CFR 164.502(b); 164.308(a)(4) |
| PRV-05 | Uses, disclosures and signed HIPAA authorizations | Federal rule | 45 CFR 164.502(a); 164.508 |
| PRV-06 | Breach response and notification | Federal rule | 45 CFR 164.404 |
| PRV-07 | Security risk analysis and risk management | Federal rule | 45 CFR 164.308(a)(1)(ii)(A), (B) |
| PRV-08 | Passwords, workstations, devices and intraoral cameras | Federal rule | 45 CFR 164.308(a)(5)(ii)(D); 164.310 |
| PRV-09 | Backups and system downtime | Federal rule | 45 CFR 164.308(a)(7) |
| PRV-10 | Email, texts, clinical photos and social media | Federal rule | 45 CFR 164.312(e); 164.502(a) |
| PRV-11 | Workforce training and sanctions | Federal rule | 45 CFR 164.530(b), (e) |
| OSH-01 | Bloodborne pathogens exposure control plan (review at least yearly) | Federal rule | 29 CFR 1910.1030(c) |
| OSH-02 | Sharps safety and the yearly safer-device review | Federal rule | 29 CFR 1910.1030(c)(1)(iv); CDC checklist I.8 |
| OSH-03 | Exposure incidents: evaluation and follow-up | Federal rule | 29 CFR 1910.1030(f)(3) |
| OSH-04 | Hepatitis B vaccination and declinations | Federal rule | 29 CFR 1910.1030(f)(2) |
| OSH-05 | Hazard communication program and safety data sheets | Federal rule | 29 CFR 1910.1200(e), (g)(8), (h) |
| OSH-06 | Amalgam separator, amalgam waste and line cleaners (model 4) | Federal rule | 40 CFR 441.30, 441.50 |
| OSH-07 | Regulated waste and sharps containers | Federal rule | 29 CFR 1910.1030(d)(4); state medical waste rules |
| OSH-08 | Eyewash and first aid | Federal rule | 29 CFR 1910.151(b), (c) |
| OSH-09 | Reporting serious work injuries to OSHA | Federal rule | 29 CFR 1904.39 |
| OSH-10 | Nitrous oxide equipment checks and scavenging | Practice decision | Manufacturer instructions |
| ST-01 | Instrument processing: receiving, cleaning, packaging, sterilizing, storage | CDC guideline | CDC checklist I.10.A |
| ST-02 | Manufacturer instructions kept at the processing area | CDC guideline | CDC checklist I.10.B |
| ST-03 | Sterilizer monitoring: each load, weekly spore test, implant loads (model 1) | CDC guideline | CDC summary 2016; checklist II.6.J |
| ST-04 | Sterilization failure and positive spore test response (model 1) | CDC guideline | CDC checklist I.10.F; CDC 2003 VI.F.8, 9 |
| ST-05 | Sterilizer maintenance and written maintenance records | CDC guideline | CDC checklist I.10.E |
| ST-06 | Single-use devices: one patient, then discard | CDC guideline | CDC summary 2016 |
| FO-01 | Phones: answering standard and routing | Practice decision | Free template: dental front desk phone scripts |
| FO-02 | Scheduling, the schedule template and the short-notice list | Practice decision | Write your own |
| FO-03 | New patients and identity at check-in | Practice decision | Write your own |
| FO-04 | Missed appointments and late arrivals | Practice decision | Free template: dental no-show policy pack |
| FO-05 | Recare: unscheduled and overdue patients | Practice decision | Free template: dental recare letter pack |
| FO-06 | Check-out and the next visit booked | Practice decision | Write your own |
| FO-07 | Records requests: intake and routing to PRV-03 | Practice decision | Free template: medical records request SOP |
| FO-08 | Opening and closing the front office | Practice decision | Free template: dental opening and closing checklist |
| FO-09 | Patient complaints, including privacy complaints | Federal rule | 45 CFR 164.530(d) for privacy complaints |
| RAD-01 | Radiation safety program and x-ray unit registration | State rule | State radiation control program |
| RAD-02 | Who may take radiographs, and the credentials on file | State rule | State dental board |
| RAD-03 | Patient selection and dose (the 2024 ADA recommendations) (model 3) | State rule | ADA, Feb 1, 2024; state rule |
| RAD-04 | Operator protection and dosimetry | State rule | State radiation control program |
| RAD-05 | Equipment inspection and quality checks | State rule | State radiation control program |
| RAD-06 | Image retention, copies and release | State rule | State law; 45 CFR 164.524 |
| IC-01 | Infection prevention program and its coordinator | CDC guideline | CDC checklist I.1.A, C |
| IC-02 | Hand hygiene | CDC guideline | CDC checklist I.5 |
| IC-03 | PPE: provided, used and laundered | Federal rule | 29 CFR 1910.1030(d)(3); CDC checklist I.6 |
| IC-04 | Respiratory hygiene and cough etiquette | CDC guideline | CDC checklist I.7.A |
| IC-05 | Safe injection practices | CDC guideline | CDC checklist I.9.A |
| IC-06 | Surfaces, barriers and blood spills | CDC guideline | CDC checklist I.11.A, E |
| IC-07 | Dental unit water quality, monitoring and boil-water response (model 2) | CDC guideline | CDC checklist I.12.A, C |
| IC-08 | Sterile water for surgical procedures | CDC guideline | CDC checklist I.12.B |
| IC-09 | Staff immunizations and TB screening | CDC guideline | CDC checklist I.3.C, G |
| IC-10 | Work restrictions for ill staff | CDC guideline | CDC checklist I.3.K |
| IC-11 | Monitoring and feedback on infection control practice | CDC guideline | CDC checklist I.4 |
| IC-12 | Medication and controlled substance storage and inventory | Federal rule | 21 CFR 1301.75(b); 1304.11(c) for DEA registrants |
| EM-01 | Emergency action plan (where a standard requires one; written above 10 employees) | Federal rule | 29 CFR 1910.38(a), (b) |
| EM-02 | Fire prevention and extinguishers | Practice decision | Local fire code |
| EM-03 | Medical emergencies: kit, AED, roles and drills (model 5) | Practice decision | State sedation permit rules where they apply |
| EM-04 | Utility failure and boil-water advisories (model 2) | CDC guideline | CDC 2003 VIII.B; checklist I.12.C |
| EM-05 | Severe weather and emergency closure | Practice decision | Write your own |
| EM-06 | Threats and workplace violence | Practice decision | State law may apply |
| HR-01 | Employee handbook (the companion document) | Practice decision | Free template: dental employee handbook |
| HR-02 | Licenses, registrations and permits on file | State rule | State dental board |
| HR-03 | Training records: HIPAA, bloodborne pathogens, chemicals | Federal rule | 45 CFR 164.530(b); 29 CFR 1910.1030(h)(2) |
| HR-04 | Form I-9 | Federal rule | 8 CFR 274a.2(b) |
| HR-05 | Timekeeping and pay records | Federal rule | 29 CFR 516.5, 516.6 |
| HR-06 | Employee exposure and vaccination records | Federal rule | 29 CFR 1910.1030(h)(1) |
| HR-07 | Separation: access removed the same day | Federal rule | 45 CFR 164.308(a)(3)(ii)(C) |
| HR-08 | Cross-training and who covers each role | Practice decision | Free template: cross-training matrix |
| FIN-01 | Patient payments at check-out and receipts | Practice decision | Write your own |
| FIN-02 | Refunds, adjustments and write-offs: who approves (model 6) | Practice decision | ACFE 2026 |
| FIN-03 | The cash drawer and the day close | Practice decision | Free template: front desk end-of-day checklist |
| FIN-04 | Deposits and separation of duties | Practice decision | Write your own |
| FIN-05 | Card on file | Practice decision | Free template: card on file policy |
| FIN-06 | Purchasing, supply orders and vendor payments | Practice decision | Write your own |
| FIN-07 | Petty cash | Practice decision | Free template: petty cash policy |
| FIN-08 | The owner's monthly money review | Practice decision | Free template: dental embezzlement checklist |
| FIN-09 | Block vacation for money roles | Practice decision | ACFE 2026 (job rotation and mandatory vacation) |
The Word file has this table of contents with a status column, the cover and control block, the numbering rules, the six model policies, the score, the revision log, the calendar and the acknowledgment pages.
Get the dental policies and procedures manualSix dental policies the template writes in full
Medical policy templates never cover sterilizer failures, waterlines, radiation or amalgam. These six are written in full in the Word file, each with a header block (owner, approver, effective date, version, review month and the rule it rests on), so the hardest dental policies are done first.
| Model policy | What it settles | Rests on |
|---|---|---|
| 1. ST-03 and ST-04 Sterilizer monitoring and failure | Mechanical check every load, an indicator in every package, a weekly spore test per sterilizer and one for every implant load; the steps after a first and a second positive test | CDC, 2016; CDC, 2003 |
| 2. IC-07 and EM-04 Waterlines and boil-water | 500 CFU/mL or less at the handpiece, testing on the maker's schedule, sterile water for surgery, what stops during a boil-water advisory and how to restart | CDC, 2016; CDC, 2003 VIII.B |
| 3. RAD-03 Radiation safety | Who may take x-rays, images chosen per patient, rectangular collimation and digital receptors, shielding per the 2024 ADA change unless the state still requires it | ADA, 2024; state rule |
| 4. OSH-06 Amalgam waste | Separator inspection, repair within 10 business days, container changes, pickups, pH 6 to 8 line cleaners, 3-year records, the June 14, 2027 date | 40 CFR 441.30, 441.50 |
| 5. EM-03 Medical emergencies | Roles in the first five minutes, monthly kit, oxygen and AED checks, a yearly drill, state permit requirements | Practice decision; state sedation permit rules |
| 6. FIN-02 Refunds, adjustments and write-offs | Reason codes, a second person's approval above a set amount, refunds back to the person who paid by the same method, the owner's monthly review | ACFE, 2026 |
Here is model 1 as it appears in the file. Highlighted text is yours to fill.
ST-03 and ST-04: Sterilizer monitoring and failure response
Owner: sterilization lead. Approved by: [owner dentist]. Effective: [date]. Version: 1.0. Rests on: CDC summary 2016; CDC 2003 VI.F.8 and 9.
Purpose. Every instrument that touches a patient has been through a sterilizer cycle we can prove worked.
- Every load: log the cycle's time, temperature and pressure from the gauge, display or printout, with the date, sterilizer, load number and operator initials.
- Every package: a chemical indicator inside, and one outside if the inside one cannot be seen. If the color did not change, do not use the instruments: reprocess them and tell the sterilization lead.
- Every week, per sterilizer: a spore test, logged with the date sent and the result. Every load that contains an implantable device gets its own spore test.
- A positive spore test: take the sterilizer out of service, review loading, packaging and cycle settings, fix what you find, then retest with biological, mechanical and chemical indicators.
- A second positive test: do not use the sterilizer until it is inspected or repaired and the cause is known. Recall, to the extent possible, and reprocess every item processed since the last negative spore test.
Records: sterilizer log ST-03-F1, spore test log ST-03-F2. State rule: [your state's sterilization monitoring and log retention requirements].
The weekly test and the implant-load test come straight from CDC: "A spore test should be used at least weekly to monitor sterilizers," and its checklist adds a spore test "with every load containing implantable items" (CDC, Summary of Infection Prevention Practices in Dental Settings, Oct 2016).
What federal rules and CDC require in writing
A handful of documents are not optional, and each comes with its own review clock and retention period. The template's calendar and retention table are built from this list.
| Document | Required by | Review | Keep records |
|---|---|---|---|
| HIPAA privacy and security policies | 45 CFR 164.530(i); 164.316(b) | Periodically, and when the law changes | 6 years from creation or last in effect |
| Bloodborne pathogens exposure control plan | 29 CFR 1910.1030(c) | At least yearly | Training 3 years; exposure records employment plus 30 years |
| Hazard communication program | 29 CFR 1910.1200(e) | When chemicals change | Safety data sheets reachable every shift |
| Emergency action plan | 29 CFR 1910.38(b) | When staff or exits change | Where a standard requires one; in writing unless 10 or fewer employees |
| Amalgam separator records | 40 CFR 441.50(b) | Inspection per the maker's manual | At least 3 years |
| Controlled substance inventory (DEA registrants) | 21 CFR 1304.11(c); 1304.04(a) | At least every 2 years | At least 2 years |
| Infection prevention policies (14 areas) | CDC dental checklist, section I | At least yearly | Sterilizer logs per state rule |
CDC's wording is the standard to hold a dental manual to: written policies "reassessed at least annually or according to state or federal requirements, and updated if appropriate," and the checklist notes this may be done during the yearly OSHA exposure control plan review. OSHA's own clock for that plan is "reviewed and updated at least annually" (29 CFR 1910.1030(c)(1)(iv)). Dental offices are partially exempt from OSHA's routine injury logs, but must still report a work-related hospitalization within 24 hours and a death within 8 (29 CFR 1904.39 and Part 1904 Appendix A).
How to number, version and retire policies
- Number by chapter: code plus two digits, for example RAD-03. Forms and logs add F and a digit, so ST-03-F1 is the sterilizer log. A retired number is never reused.
- Version by impact: 1.0 for the first approved text; a change to what anyone does moves the whole number, a wording fix moves the decimal.
- Head every policy with its owner, approver, effective date, version, next review month, the rule it rests on, and its procedure and forms.
- Approve before it takes effect: the owner dentist signs and the revision log is updated first. A changed HIPAA policy is documented before its effective date (45 CFR 164.530(i)).
- Keep one current copy in the shared folder; the day a new version takes effect, the old one is marked superseded, moved to the archive and kept 6 years.
The same scheme runs through the medical office policies and procedures manual, so a practice with medical and dental sides can keep one numbering system. The medical binder's download is the companion for the medical chapters; the dental file adds the sterilization, radiation and amalgam chapters and the six model policies.
The annual review calendar
One chapter a month keeps the review small enough to happen. Each month also has fixed items: March is the exposure control plan and safer-device review, April the sterilizer log audit, June the x-ray registration dates, August the emergency drill and kit check.
| Date | What changes | Policies to update | Rule |
|---|---|---|---|
| June 14, 2027 | A separator installed before June 14, 2017 that does not meet the current standard must be replaced | OSH-06 | 40 CFR 441.30(a)(1)(iii) |
| July 17, 2027 | Access requests answered within 15 calendar days, one extension of up to 30; no fee for inspection or portal access; fee schedule posted if you charge for copies; no signed privacy notice acknowledgment | PRV-02, PRV-03, FO-07 | HHS final rule 2026-23429 (effective Jan 18, 2027) |
Until July 17, 2027, the current access rule (30 days, with one 30-day extension) and the signed acknowledgment still apply. The records request process guide walks through the intake that FO-07 routes to PRV-03.
Why a written binder matters for a dental office
The cost of a missing manual shows up in an investigation, not in a normal week. The Shen Smiles case began with a patient's attorney complaining in April 2020 that records requests went unanswered; the practice could not show HHS the required policies and safeguards and settled for $140,000, after a 90% reduction because it was a small rural practice (HIPAA Journal, Oct 9, 2026; HHS pages block automated reading). HIPAA Journal counted 21 settlements and civil monetary penalties announced by the HHS Office for Civil Rights in 2025 (HIPAA Journal compilation; trade press).
The money handling chapter answers those three weaknesses directly: FIN-02 makes a second person approve refunds and adjustments, FIN-04 separates who takes payments from who deposits them, and FIN-08 puts the owner's monthly review on the calendar. The dental office embezzlement checklist is that 30-minute review. When the gap is bigger than a binder (procedures nobody follows, a task board nobody owns, cash controls that exist on paper), the Fix one system offer installs Practice Controls: the SOP library, the recurring task board, the compliance calendars and the cash controls, built inside the tools you already use.
Worked example: a two-dentist office builds its manual
A two-dentist family practice with 12 staff kept its policies in a binder from the former owner, a folder of OSHA forms and the office manager's memory. The manager marked the 82-slot table of contents in one afternoon. Illustrative numbers, not a client; the gap worksheet is in the Word file.
| Finding or line | Count | Hours |
|---|---|---|
| Policies found anywhere | 27 | Not scored |
| A. Federal and state rule slots missing | 16 | 16 x 3 = 48 |
| B. CDC guideline slots missing (water quality, boil-water, work restrictions) | 9 | 9 x 2 = 18 |
| C. Policies past their review date | 21 | 21 x 1 = 21 |
| D. Staff with no signed acknowledgment | 12 | 12 x 0.25 = 3 |
| Total | Readiness score 30 of 100 | 90 hours |
At four hours a week that is about 23 weeks. The manager adopted the six model policies in the first month, found that the amalgam separator dated from 2015 and booked its replacement ahead of June 14, 2027, then worked the Federal rule slots and put the calendar on the task board. Five months later the score was 85; the open items were the yearly owner sign-off and the July 2027 HIPAA updates, both dated.
When it goes wrong
- The amalgam separator alarms. Repair or replace it within 10 business days and log it (40 CFR 441.30(a)(1)(v)).
- Two versions of a policy are in use. Withdraw the old one the day you find it, archive it, retrain the people affected and log both versions.
- A staff member is hurt and admitted to hospital. Report to OSHA within 24 hours, even though dental offices skip the routine injury logs.
- A policy exists but nobody follows it. Retrain and apply it, or change it. A written rule nobody follows reads worse in an investigation than an honest gap.
Mistakes to avoid
- Using a medical template for a dental office. It has no sterilization, radiation or amalgam chapter, which are the three an inspector in a dental office asks about.
- Keeping the old shielding rule. A radiation policy written before Feb 2024 likely still requires aprons and collars; update it to the ADA recommendation unless your state requires shielding.
- Mixing the handbook and the manual. Pay, leave and conduct belong in the dental employee handbook; how the office runs belongs here.
- Logs with no policy, or a policy with no log. Every policy names its forms (ST-03-F1 for the sterilizer log), and every log points back to a policy.
- Reviewing everything in December. One chapter a month is the only pace that survives a busy year.
- Name the manual owner, the privacy official, the safety lead, the infection prevention coordinator and the sterilization lead.
- Mark every slot in the table of contents Have, Draft or Missing, and delete the ones that do not apply.
- Adopt model 1 (sterilizer) and model 2 (waterlines and boil-water) first; they protect patients directly.
- Check your amalgam separator's install date against June 14, 2027 and your radiation policy against the 2024 ADA recommendation.
- Put the twelve review months and the two 2027 dates on your recurring task board.
By the numbers
| Figure | What it measures | Source and year |
|---|---|---|
| 82; 32; 7; 17; 26 | Template slots; tied to federal rules, state rules, CDC guidance; practice decisions | ClinicOps count, 2026 |
| 14 areas; at least annually | Written infection prevention policies CDC's dental checklist expects, and how often to reassess them | CDC, 2016 |
| Weekly; every implant load | Spore test frequency per sterilizer | CDC, 2016 |
| 500 CFU/mL | Maximum heterotrophic bacteria in dental unit output water | CDC, 2016 |
| 10 business days; 3 years; June 14, 2027 | Separator repair deadline; record retention; replacement date for older noncompliant separators | 40 CFR 441.30, 441.50 |
| 6 years | Keeping HIPAA policies from creation or the date last in effect | 45 CFR 164.530(j) |
| 15 days; July 17, 2027 | New access deadline and its compliance date | HHS final rule, 2026 |
| $140,000 | HIPAA settlement with a Pennsylvania dental practice, Oct 2026 | HIPAA Journal, 2026 |
| 21 | Federal HIPAA settlements and penalties announced in 2025 | HIPAA Journal compilation |
| 33%; 19%; 18% | Frauds from missing controls, overridden controls, no management review | ACFE, 2026 |
| $126,000; $100,000 | Median fraud loss, organizations under 100 employees; health care | ACFE, 2026 |
| 24 hours; 8 hours | Reporting a work hospitalization; a work death, to OSHA | 29 CFR 1904.39 |
- Dental practice operations library
Every system for a dentist-owned office, front desk to cash controls.
- SOPs, controls and compliance
The pillar this manual belongs to, with the compliance calendar in full.
- The operations system library
The full library of systems behind the binder.
- Dental employee handbook template
The employment rules the HR chapter points to.
- Dental office daily checklist
Where the sterilizer, waterline and amalgam logs get filled in every day; the opening and closing checklist splits it by role.
- OSHA exposure control plan template
The plan behind OSH-01, reviewed every March.
- Dental front desk training manual
The front office chapter, taught to a new hire; the manual download goes with it.
- How to write an SOP a new hire can run
Turning each policy into the steps behind it.
- What a dental operations consultant does
When you want the controls built and kept current for you.
One binder, numbered, current and signed
The Word file gives you the 82-slot table of contents, the six dental model policies, the score, the revision log and the calendar with the 2027 dates. If the binder keeps drifting from what the office actually does, the Chaos Audit finds the one fix to run first.
Frequently asked questions
What should be in a dental office policies and procedures manual?
A cover with the owner and version, numbering rules, and policies in ten areas: governance and records, HIPAA privacy, OSHA safety, sterilization, the front office, radiation safety, infection control, emergencies, people and money handling. It also needs a revision log, a review calendar and signed staff acknowledgments. This template has 82 slots and six dental policies written in full.
Is a dental office required to have written policies and procedures?
Yes, for several areas. HIPAA requires written privacy and security policies, OSHA requires a written exposure control plan and hazard communication program, and where an OSHA standard calls for an emergency action plan it must be in writing above 10 employees. CDC's dental guidance also expects written infection prevention policies, from sterilization to waterlines.
How often should dental office policies be reviewed?
At least once a year. CDC asks dental offices to reassess infection prevention policies at least annually, OSHA requires the exposure control plan to be reviewed and updated at least annually, and HIPAA requires periodic review and updates when the law changes. The template reviews one chapter a month.
How long do we keep old versions of policies?
Keep HIPAA privacy and security policies for 6 years from the date they were created or last in effect, whichever is later. The template applies the same 6-year clock to every policy version, and its retention table lists the other records, such as 3 years for amalgam separator logs.
Do dental offices still need lead aprons and thyroid collars?
The ADA said on Feb 1, 2024 that lead aprons and thyroid collars are no longer recommended for dental x-rays, favoring rectangular collimation and digital receptors. Some states may still require shielding, so the template's radiation policy has a line for your state's rule, and the state rule wins where it applies.
What is the difference between an employee handbook and a policies and procedures manual?
The handbook sets the terms of employment: pay, time off, conduct and leaving. The manual sets how the office runs: sterilization, radiation, privacy, emergencies and money handling. Keep them separate so a change to a sterilizer procedure does not mean reissuing the handbook.